You can view images from the video by shuttling.

Steps for replacing the fill chamber door gasket:

Tools: Phillips screw driver, T-15 torx driver

  1. Move the chamber door gasket out of the way – take off bottom hinges only and flip the door up on top of the machine.
  2. Take out all of the screws holding on the gasket.  Find them by lifting the lip of the gasket .
  3. Remove the old gasket
  4. Put the new gasket in place and use the same hols and screws to put the new gasket on.
  5. Be careful to turn the screws down far enough so they cannot be felt when you run your finger over the outside.  If you can feel the screw from outside the gasket, screw it down a little further.  If you go to far the rubber from the gasket can slip out/squeeze out around the screw.
  6. Replace the swing arms on the chamber door
  7. Test a cartridge.
  8. The best way to test how well you replaced the gasket is to refill a cartridge and see if the chamber door seals properly.